1. Board Calibration
- Check board caliper with proper instrument
- Dial in proper calibration on equipment
• Use designated tab knife for type of board (flute) being run.
• Green = B-flute
• Red = C-flute
• Black = Doublewall
• Yellow = triplewall/doublewall depending on weight of paper
• Check for proper alignment of male slot knife and stitch block
• Mount female stitch head on shaft
• Mount female slot knife, spacer and pinch knife to head
• With a magnetic base dial indicator, check the run out of the pinch blade.
• If run out exceeds 0.003 to 0.004 inch slightly loosen the attachment bolts.
• With a soft faced hammer, tap the pinch knife until you achieve 0.004 inch or less total indicator run out.